{"id":70,"date":"2024-07-03T20:00:58","date_gmt":"2024-07-03T20:00:58","guid":{"rendered":"https:\/\/psychlabs.colostate.edu\/dnlab\/?page_id=70"},"modified":"2024-07-08T17:14:13","modified_gmt":"2024-07-08T17:14:13","slug":"equipment","status":"publish","type":"page","link":"https:\/\/psychlabs.colostate.edu\/dnlab\/?page_id=70","title":{"rendered":"Lab Equipment"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Clark Building Equipment<\/h2>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-70_863317-72 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-70_863317-72 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-70_863317-72\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">fNIRS<\/h2>\n\n\n\n<p>The lab uses a 48 source x 32 detector <a href=\"https:\/\/nirx.net\/nirscout\" data-type=\"link\" data-id=\"https:\/\/nirx.net\/nirscout\">NIRx NIRScout Extended<\/a> system for functional near infrared spectroscopy. This is an LED based (670 and 850 nM), continuous wave device. The system is equipped with <a href=\"https:\/\/nirx.net\/nirscap\" data-type=\"link\" data-id=\"https:\/\/nirx.net\/nirscap\">commercial cap<\/a> and custom optode holders. Up to 32 <a href=\"https:\/\/nirx.net\/short-channels\" data-type=\"link\" data-id=\"https:\/\/nirx.net\/short-channels\">short distance channels<\/a> can be configured to measure non-brain physiological noise signals. Individual optodes can be placed in caps with or without the use of spring loading assistance.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-1024x768.jpg\" alt=\"\" class=\"wp-image-110\" srcset=\"https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-1024x768.jpg 1024w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-300x225.jpg 300w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-768x576.jpg 768w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-1536x1152.jpg 1536w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-2048x1536.jpg 2048w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2019-676x507.jpg 676w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">EEG<\/h2>\n\n\n\n<p>A <a href=\"https:\/\/www.gtec.at\/product\/ghiamp\/\" data-type=\"link\" data-id=\"https:\/\/www.gtec.at\/product\/ghiamp\/\">g.tec g.HiAmp active EEG system<\/a> is available. The system can be configured with up to 144 electrodes (128 active + 16 other). A variety of sensors are available including <a href=\"https:\/\/www.gtec.at\/product\/g-scarabeo-eeg-electrodes\/\" data-type=\"link\" data-id=\"https:\/\/www.gtec.at\/product\/g-scarabeo-eeg-electrodes\/\">active<\/a> and passive wet electrodes and <a href=\"https:\/\/www.gtec.at\/product\/g-sahara-hybrid-eeg-electrodes\/\" data-type=\"link\" data-id=\"https:\/\/www.gtec.at\/product\/g-sahara-hybrid-eeg-electrodes\/\">active dry <\/a>electrodes, all for use in commercial cap-based montages.<\/p>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-70_134169-ea .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-70_134169-ea .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-70_134169-ea\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-768x1024.jpg\" alt=\"\" class=\"wp-image-97\" srcset=\"https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-768x1024.jpg 768w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-225x300.jpg 225w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-1152x1536.jpg 1152w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-1536x2048.jpg 1536w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-676x901.jpg 676w, https:\/\/psychlabs.colostate.edu\/dnlab\/wp-content\/uploads\/sites\/16\/2024\/07\/IMG_2389-scaled.jpg 1920w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Translational Medicine Institute<\/h2>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-70_6f7ee5-43 .kt-block-spacer{height:60px;}.wp-block-kadence-spacer.kt-block-spacer-70_6f7ee5-43 .kt-divider{border-top-width:1px;height:1px;border-top-color:#eee;width:80%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-70_6f7ee5-43\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">MRI<\/h2>\n\n\n\n<p>A 3T Siemens Skyra MR scanner is available for research use. The scanner is located in the <a href=\"https:\/\/vetmedbiosci.colostate.edu\/tmi\/\" data-type=\"link\" data-id=\"https:\/\/vetmedbiosci.colostate.edu\/tmi\/\">Translational Medicine Institute <\/a> on the CSU Veterinary Medicine Campus. TMI is about a 15 minute walk from the Behavioral Sciences Building.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Clark Building Equipment fNIRS The lab uses a 48 source x 32 detector NIRx NIRScout Extended system for functional near infrared spectroscopy. This is an LED based (670 and 850 nM), continuous wave device. The system is equipped with commercial cap and custom optode holders. Up to 32 short distance channels can be configured to [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","footnotes":""},"class_list":["post-70","page","type-page","status-publish","hentry","post-preview"],"taxonomy_info":[],"featured_image_src_large":false,"author_info":{"display_name":"rojasd","author_link":"https:\/\/psychlabs.colostate.edu\/dnlab\/?author=6"},"comment_info":0,"_links":{"self":[{"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=\/wp\/v2\/pages\/70","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=70"}],"version-history":[{"count":10,"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=\/wp\/v2\/pages\/70\/revisions"}],"predecessor-version":[{"id":114,"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=\/wp\/v2\/pages\/70\/revisions\/114"}],"wp:attachment":[{"href":"https:\/\/psychlabs.colostate.edu\/dnlab\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=70"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}